5 Volt 6 Amp Battery Tester
BTS4000-5V6A | Battery Testing System
Battery testing machine for any rechargeable battery with-in the range of 0 - 5V system, capable of handling 0 - 6 amps for cycle testing to test the battery. RPE teams up with Neware to bring you a battery tester for all your battery testing needs.
This Item is In Stock!
Package Contains:
- Aligator Battery clamps
- 1 Battery Tester System
- 1 Master Unit Control System
- User Manual System
Items Values
- Input AC AC 110V ±10% / 50Hz
- Input power 709 W
- Resolution AD:16bit;DA:16bit
- Input impendence ≥1MΩ
Voltage
- CV output range 0.025V~5V
- Min discharge voltage 2.5V
- Accuracy ± 0.1% of FS
- Stability ± 0.1% of FS
Current
- Output range/channel 0.05A~10A
- Accuracy ± 0.1% of FS
- CV cut-off current 0.02A
- Stability ± 0.1% of FS
Power
- Output power/channel 50 W
- Stability ± 0.2% of FS
Time
- Current response time Max rising time:20ms
- Working step time ≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms)
Data
Data record conditions
- Min data record interval:100ms
- Min voltage change:10mV
- Min current change:20mA
- Frequency 10Hz
Charge
- Charge modes CC、CV、CCCV、CP、CCCV for battery pack
- Cut-off condition Voltage、Current、Time、Capacity、-△V
Discharge
- Discharge modes CV、CP、CR
- Cut-off condition Voltage、Current、Time、Capacity、-△V
Pulse
- Charge CC、CP
- Discharge CC、CP
- Min pulse width 500ms
- Pulse counts Up to 32
- Chg and Dischg switch Supported
- Cut-off condition Voltage、Time
- DCIR Supported
- CH parallel output current > 100A, then supported, in parallel mode pulse function is disabled
Cycles
- Max cycles 65535
- Max steps 254
Nest 3
- Power-off data protection
Protection
- Off-line operation mode
- User-defined protection conditions, such as
- upper and lower limited current/voltage, delay
- time, temperature, etc.
Hardware protection
- Full proof protection with hardware protection level IP20
Channels feature
- Independent pairs of closed-loop for constant
Channels control
- mode Independent control
Data acquisition method
- Kelvin connection
- Noise <85dB
- Database MySQL
- Communication TCP/IP
- Data Export Excel, TXT, PDF
- Disk space 500GB
- Leak current 0.005mA
- OS Windows 7,
- Communication port Ethernet port
Operation and storage environment requirement
- Items Values
- Operation environment temperature
- 0℃~40℃ (When the temperature is 25±10℃, the
- accuracy error caused by temperature change is less than50ppm /℃)
- Storage environment temperature -10℃~50℃
- Operation environment humidity ≤70% RH(no moisture condensation)
- Storage environment humidity ≤80% RH(no moisture condensation)